LOW POWER GROUND FAULT INTERRUPTER
DESCRIPTION
The UTC GV4145-Q is a low power controller for AC outlet
ground fault interrupters. These devices detect hazardous grounding
conditions, such as equipment (connected to opposite phases of the
AC line) in contact with a pool of water and open circuits the line
before a harmful or lethal shock occurs.
Contained internally are a 26V zener shunt regulator, an opamp,
and an SCR driver. With the addition of two sense transformers, a
bridge rectifier, an SCR, a relay, and a few additional components,
the UTC GV4145-Q will detect and protect against both hot wire to
ground and neutral wire to ground faults. Ease of application and
long-term reliability.
FEATURES
* No potentiomenter required
* Direct interface to SCR
* Supply voltage derived from AC line-26V shunt
* Adjustable sensitivity
* Grounded neutral fault detection
* 450μA quiescent current
* I deal for 120V or 220V systems |